Abstract
SUMMARY The axial diffusion of a passive scalar field (e.g. temperature) in Poiseuille flow through a duct is considered, taking account of leakage of heat through the duct boundary. The cases of the two-dimensional channel and the pipe of circular cross-section are considered in detail, and it is shown that (i) the centroid of the scalar field moves (asymptotically) with a velocity intermediate between the mean and the maximum flow rates and increases with increasing wall conductance, and (ii) the effective diffusivity in the flow direction is a decreasing function of wall conductance. The temperature field downstream of a maintained heat source is determined as a function of wall conductance.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.