Abstract

This paper investigates the use of switching frequency modulation in the reduction of the differential-mode conducted electromagnetic interference (EMI) of the offline boost power-factor correction converter. In particular, the EMI benefits obtained with modulation frequencies at and in excess of twice the line frequency are considered, incorporating the influence of average and quasi-peak (QP) detectors into the analysis and measurements. It is concluded that there is no significant change in the QP measurement unless the modulation frequency exceeds half the resolution bandwidth; however, up to 8-dB reduction in the average measurement, with no change in the QP measurement, can be obtained with modulation at twice the line frequency, for a switching frequency deviation of 20%. A digital modulation algorithm was devised and implemented using a digital-signal-processor-controlled converter. The reduction in the average detector measurement obtained for the digital modulation was comparable to that predicted for the linear modulation, but it delivers a more well-defined and predictable conducted EMI spectrum.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.