Abstract

BackgroundThis study was conducted to evaluate the effect of radiation exposure and storage time on the degree of conversion (DC%) and flexural strength (FS) of three different resin composites. In total, 90 disk-shaped, and 360 rod-shaped composite specimens were prepared to evaluate the DC% and FS, respectively. Specimens were divided into 18 groups (DC%: n = 5 and FS: n = 20) according to the three experimental factors of the study: 1—Radiation (no-exposure and exposure), 2—Resin composite material (Herculite XRV Ultra, Z250 XT and Grandio), and 3—Storage time (24 h in distilled water, 3-m and 6-m in 70% ethanol). Fourier transform infrared spectrometer (FTIR) was used to determine the DC%. For FS, the specimens were subjected to a three-point bending test at 1 mm/min crosshead speed. Data were analyzed using three-way ANOVA/Tukey HSD test. Significant level was set at P = 0.05.ResultsFor DC%, there was no significant difference between no-radiation exposure and radiation exposure (P > 0.05). Herculite XRV Ultra revealed the highest statistically significant DC% (P < 0.05). The 24-h storage time revealed the least significant DC% (P < 0.05). For FS, radiation exposure showed a statistically significant higher value compared to no-radiation exposure (P < 0.05). Herculite XRV Ultra showed the least FS value (P < 0.05). The 24-h storage time showed the highest significant value (P < 0.05).ConclusionsRadiation exposure has no significant impact on the DC% of the different resin composites, but it has a significant positive effect on the FS. Storage time had a significant effect on both DC% and FS.

Highlights

  • This study was conducted to evaluate the effect of radiation exposure and storage time on the degree of conversion (DC%) and flexural strength (FS) of three different resin composites

  • For factor storage time (Table 5), there was no statistically significant difference between 3-m and 6-m storage times (P > 0.05). Both 3-m and 6-m storage times showed statistically significant higher DC% compared to 24-h storage time (P < 0.05)

  • For the effect of factor storage time on the DC% of the different resin composites, the results showed that both 3-m and 6-m storage time exhibited statistically significant higher DC% values compared to 24-h storage time (Table 5)

Read more

Summary

Introduction

This study was conducted to evaluate the effect of radiation exposure and storage time on the degree of conversion (DC%) and flexural strength (FS) of three different resin composites. Specimens were divided into 18 groups (DC%: n = 5 and FS: n = 20) according to the three experimental factors of the study: 1—Radiation (noexposure and exposure), 2—Resin composite material (Herculite XRV Ultra, Z250 XT and Grandio), and 3—Storage time (24 h in distilled water, 3-m and 6-m in 70% ethanol). Its adverse effects on the patients’ general health and their quality of life are, quite significant (Yucel et al 2014). Secondary effects of radiotherapy on the oral tissues have been studied widely. Increasing filler percentage within contemporary resin composites was found to adversely influence the degree of conversion (Rastelli et al 2012; Halvorson et al 2009). It was observed that flexural strength of resin-based composites is greatly

Objectives
Results
Discussion
Conclusion
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call