Abstract

BackgroundGa-labeled radiotracers are increasingly used for PET imaging. During the labeling procedure, formation of 68Ga-colloid may occur. Upon i.v. injection, 68Ga-colloid will accumulate rapidly in the liver, spleen, and bone marrow, resulting in reduced target-to-background ratios. In this study, we applied a thin layer chromatography (TLC) method to measure colloid content and we studied the effect of the purification method on the in vivo characteristics of 68Ga-labeled DOTA-exendin-3.DOTA-exendin-3 was labeled with 68Ga, and the colloid content was measured by TLC on silica gel ITLC with two mobile phases. The labeling mixture was purified by gel filtration on a 5-ml G25M column, by reversed-phase high-performance liquid chromatography (RP-HPLC) using a C8 column or by solid phase extraction (SPE) on an HLB cartridge. The in vivo characteristics of the preparations were determined in BALB/c nude mice, and PET images were acquired 1 h p.i. using a microPET scanner. In these studies, unpurified 68Ga-DOTA-exendin-3 and 111In-DOTA-exendin-3 were used as a reference.ResultsThe colloid content of 111In-DOTA-exendin-3 and unpurified, gel filtration, RP-HPLC- and SPE-purified 68Ga-DOTA exendin-3 was <3, 7, 9, <3, and <3 %, respectively. Unpurified 68Ga-DOTA exendin-3 showed high liver and spleen uptake. Gel filtration partly removed 68Ga-colloid from the preparation, resulting in moderate liver and spleen SPE-purified 68Ga-DOTA exendin-3 showed very low liver and spleen uptake, that was similar to that of RP-HPLC purified 68Ga-DOTA exendin-3.ConclusionsWe showed that the colloid content can be measured by TLC and that solid phase extraction and HPLC completely remove 68Ga-colloid from 68Ga-labeled tracer preparations, resulting in very low liver and spleen uptake. This study clearly shows the importance of removal of 68Ga-colloid from preparations.

Highlights

  • Ga-labeled radiotracers are increasingly used for positron emission tomography (PET) imaging

  • We previously showed that insoluble 68Ga-species can be removed from the labeling reaction of 68Ga-labeled DOTA-exendin-3, a tracer targeting the glucagon-like peptide-1 receptor (GLP-1R), using reversed-phase high-performance liquid chromatography (RP-HPLC) [3]

  • We examined the effect of the purification method on the in vivo characteristics of 68Ga-DOTAexendin-3 in BALB/c nude mice. 68Ga-DOTA-exendin-3 was purified by reversed-phase highperformance liquid chromatography (RP-HPLC), gel filtration, or solid phase extraction

Read more

Summary

Introduction

Ga-labeled radiotracers are increasingly used for PET imaging. During the labeling procedure, formation of 68Ga-colloid may occur. We applied a thin layer chromatography (TLC) method to measure colloid content and we studied the effect of the purification method on the in vivo characteristics of 68Ga-labeled DOTA-exendin-3. The in vivo characteristics of the preparations were determined in BALB/c nude mice, and PET images were acquired 1 h p.i. using a microPET scanner. In these studies, unpurified 68Ga-DOTA-exendin-3 and 111In-DOTAexendin-3 were used as a reference. Because of all these characteristics, there is an increasing interest in the application of 68Ga-labeled peptides

Methods
Results
Discussion
Conclusion

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.