Abstract

A simple experimental model was used to examine the relationship between modulation and hazard for thermal bioelectromagnetic effects. The inner forearms of 11 human volunteers were exposed to continuous and pulse-modulated thermal radiation from an incandescent light source. The time of irradiation required to produce threshold pain sensation was measured as a function of the average power density (450-2500 m W cm-2), pulse repetition frequency (continuous, 0.4 Hz, 8.0 Hz) and duty cycle (continuous, 0.33, 0.50). The resulting 32 sets of data could be described by a single power function expression which relates time and power density through a regression slope. The slope was found to depend on the modulation of the radiation, but not on the age of the subject or wet bulb globe temperature (WBGT). The minimum average power density which could elicit pain within 200 sec (an effective threshold intensity) was determined to be independent of modulation, regression slope, subject age and WBGT.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.