Abstract

An experimental investigation of the effect of mean stress on the fatigue life and corrosion fatigue life of cylindrical specimens is presented. Force controlled constant amplitude axial fatigue tests in the regime of 105 to 107 cycles were conducted for two different environments: in air (without corrosion) and in-situ in a corrosive environment, 0.824% NaCl aqueous solution flow. The test results are assessed with respect to various standard models of mean stress influence on fatigue. The reduction in material fatigue strength due to the corrosion environment is evaluated and the results obtained show that in a low salinity aqueous corrosive solution, the fatigue strength at 4x106 is reduced of a factor of 2 compared to no corrosion tests.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.