Abstract

One-dimensional (1-D) numerical simulations were carried out of two vertical heated parallel- channel experiments using a linear frequency domain approach to investigate the wall energy storage effect on the system's stability boundary for supercritical water up-flow. Oscillatory instability boundaries of the experimental cases with two different wall thicknesses, uniform and non-uniform power distributions are produced, assessed and discussed. In all, 31 cases were examined. These instability predictions with wall energy storage effects are compared with experimental data and other numerical results obtained without wall heat effects. There is improved agreement on the stability boundary predictions when the wall energy storage effect is included; however, all results fall within the experimental uncertainty. There is a cancellation effect of the wall energy storage in two parallel channels compared to a single channel. Consequently, the effect of wall energy storage is relatively small for the experiments modeled.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.