Abstract
To find the relationship between the modal frequency of HDD actuator arm and the interested process parameter, the pivot bearing insertion process has been investigated. The non-conformance condition could be induced by various parameters such as the dimension of parts, and the friction inside the bearing. One of the interesting parameter is the depth of the glue groove between the pivot bearing and the actuator arm. The objective of this research is to prove the existence of relationship between depth of the glue groove and the actuator arm modal frequency. The variation of the modal frequency of actuator arm is investigated by the experiment and FEM. Representing the variation of the controlled parameter, the depth of the glue groove has been varied. The modal frequency of each specimen is measured and is compared to the expected standard condition. The experiment shows that the modal frequency of some vibration mode is significantly different in each group of specimen. The experiment results and the FEM results show the relationship between the variation of controlled dimension and the modal frequency of the Actuator Arm.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.