Abstract

Combinational logic soft errors are expected to be the dominant reliability issue for advanced technologies. One of the major factors affecting the soft-error rates is single-event transient (SET) pulse widths. The SET pulse widths, which are controlled by drift, diffusion, and parasitic bipolar transistor parameters, are a strong function of operating temperature. In this work, heavy-ion induced SET pulse widths are reported at temperatures ranging from 25° to 100° C with an autonomous SET capture circuit. Experimental and simulation results in a 90nm bulk CMOS technology indicate an increase as high as 37% in average SET pulse width with increasing operating temperature, with some pulses almost 2 ns long at higher temperatures. The increase in the SET pulse width can be explained by the dependence of bipolar amplification on temperature.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.