Abstract

ABSTRACTBackground: To demonstrate the effect of preoperative higher order aberrations (HOAs) on postoperative residual astigmatism in toric intraocular lens (IOL) implantation.Methods: A retrospective, controlled, comparative study that involved patients who underwent toric IOL implantation. Patients were divided into two groups according to the difference between the estimated residual astigmatism and actual postoperative astigmatism [difference ≤0.5 diopters (D), Group A; difference >0.5 D, Group B]. Corneal astigmatisms with axis, and various aberration values were compared between the two groups.Results: Total RMS and HOA RMS values in Group B were significantly higher than those in Group A (p < .001, = 0.003). The vertical coma value, and its absolute value, in Group B were significantly higher than those in Group A (p < .001, = 0.002). The total RMS and absolute value of the vertical coma showed a positive linear correlation with the degree of residual postoperative astigmatism (R-square = 0.139, 0.131; p = .027, 0.036).Conclusions: If the residual astigmatism after insertion of the toric IOL was greater than expected, corneal aberrations, shown by total RMS and HOA RMS values before surgery, especially of the vertical coma, tended to be high.