Abstract

Objective: To evaluate the effect of an arm sling on gait speed and energy efficiency of patients with hemiplegia. Design: A randomized crossover design. Setting: A rehabilitation department of a university hospital. Subjects: Thirty-seven outpatients with hemiplegia were included in this study. Interventions: All patients walked on a 20-m walkway twice on the same day, randomly with and without an arm sling, at a self selected speed. Main measures: The heart rate, gait speed, oxygen cost and oxygen rate were measured on all patients. We analysed all values with and without an arm sling and also compared them after all patients being stratified according to demographic and clinical characteristics. Results: When we compared the heart rate between walking with (90.7 ± 17.2 beats/min) and without (91.2 ± 18.6 beats/min) the arm sling, it was significantly decreased while walking with the arm sling. When we compared the gait speed between walking with (32.8 m/min) and without (30.1 m/min), it was significantly increased with the arm sling walking. The O2 rate in hemiplegic patients walking with the arm sling was significantly decreased by 7%, compared to walking without arm sling (5.8 mL/kg min and 6.2 mL/kg min, respectively). The O2 cost in hemiplegic patients walking without arm sling was significantly 1.4 times greater than walking with it (0.2 mL/kg m and 0.3 mL/kg m, respectively). Conclusion: An arm sling can be used to improve the gait efficiency.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call