Abstract

Super-duplex stainless steels are recently developed high alloyed stainless steels that combine good mechanical properties with excellent corrosion resistance. Because of a high content of chromium and molybdenum, these alloys are susceptible to σ-phase precipitation during short exposure to temperatures between 650 and 950°C. The effect of 800°C aging on σ-phase formation and on the mechanical properties of a super-duplex stainless steel have been reported previously by the authors. 1 This investigation concerns the effect of σ-phase precipitation at 800°C on the corrosion behaviour in seawater and comprises anodic polarization scans and potentiostatic crevice corrosion tests. A serious deterioration of the corrosion resistance is found after aging times longer than 7 min, resulting in a drop of both the critical crevice corrosion temperature (CCT) and the breakdown potential ( E bd). The initiation of localized corrosion takes place next to the σ-phase, in the newly formed secondary austenite ( γ 2).

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.