Abstract

Abstract. We describe a dynamic chamber system to determine reactive trace gas exchange fluxes between plants and the atmosphere under laboratory and, with small modifications, also under field conditions. The system allows measurements of the flux density of the reactive NO-NO2-O3 triad and additionally of the non-reactive trace gases CO2 and H2O. The chambers are made of transparent and chemically inert wall material and do not disturb plant physiology. For NO2 detection we used a highly NO2 specific blue light converter coupled to chemiluminescence detection of the photolysis product, NO. Exchange flux densities derived from dynamic chamber measurements are based on very small concentration differences of NO2 (NO, O3) between inlet and outlet of the chamber. High accuracy and precision measurements are therefore required, and high instrument sensitivity (limit of detection) and the statistical significance of concentration differences are important for the determination of corresponding exchange flux densities, compensation point concentrations, and deposition velocities. The determination of NO2 concentrations at sub-ppb levels (<1 ppb) requires a highly sensitive NO/NO2 analyzer with a lower detection limit (3σ-definition) of 0.3 ppb or better. Deposition velocities and compensation point concentrations were determined by bi-variate weighted linear least-squares fitting regression analysis of the trace gas concentrations, measured at the inlet and outlet of the chamber. Performances of the dynamic chamber system and data analysis are demonstrated by studies of Picea abies L. (Norway Spruce) under field and laboratory conditions. Our laboratory data show that the quality selection criterion based on the use of only significant NO2 concentration differences has a considerable impact on the resulting compensation point concentrations yielding values closer to zero. The results of field experiments demonstrate the need to consider photo-chemical reactions of NO, NO2, and O3 inside the chamber for the correct determination of the exchange flux densities, deposition velocities, as well as compensation point concentrations. Under our field conditions NO2 deposition velocities would have been overestimated up to 80%, if NO2 photolysis has not been considered. We also quantified the photolysis component for some previous NO2 flux measurements. Neglecting photo-chemical reactions may have changed reported NO2 compensation point concentration by 10%. However, the effect on NO2 deposition velocity was much more intense, ranged between 50 and several hundreds percent. Our findings may have consequences for the results from previous studies and ongoing discussion of NO2 compensation point concentrations.

Highlights

  • Nitric oxide (NO), nitrogen dioxide (NO2), often denoted as nitrogen oxides (NOx), and ozone (O3) are important compounds in atmospheric chemistry

  • Our laboratory data show that the quality selection criterion based on the use of only significant NO2 concentration differences has a considerable impact on the resulting compensation point concentrations yielding values closer to zero

  • In this paper we presented a dynamic chamber system for surface exchange flux measurements of reactive and nonreactive trace gases on plants under field and laboratory conditions

Read more

Summary

Introduction

Nitric oxide (NO), nitrogen dioxide (NO2), often denoted as nitrogen oxides (NOx), and ozone (O3) are important compounds in atmospheric chemistry. NOx has an important role in radical chemistry and in the chemical formation and destruction of tropospheric and stratospheric O3 (Crutzen, 1979). C. Breuninger et al.: The dynamic chamber method to study trace gas exchange (remote sites) up to 1000 ppb (urban environments). Typical ambient non-urban NO2 concentrations are 0.05 to 1 ppb (Lerdau et al, 2000). Mean annual mixing ratios of NO2 are up to 20 ppb in urban or industrialized regions, or 5 ppb in regions of little industrial activity. During smog events the NO2 concentration may exceed 1 ppm (Stulen et al, 1998)

Methods
Results
Discussion
Conclusion
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call