Abstract
Selenium is one of the hazardous trace elements emitted from coal-fired power plants. The distribution of selenium in Wet Flue Gas Desulfurization (WFGD) process is still unclear and even in controversial, impeding the development of selenium removal technologies. This research has found that the selenite in simulated slurry could be reduced by SO2 while selenate has not been affected. Characterization methods including X-ray diffraction (XRD) and X-ray photoelectron spectroscopy (XPS) were used to provide an evidence that the product of the reduction reaction is amorphous elemental selenium. Meanwhile, the influences of other gaseous components, pH, temperature and S2O82− in simulated slurry has also been considered in this research. It is found that with the increase of SO2 concentration in flue gas, the reduction of selenite increased and the reduction reaction is an exothermic reaction. Meanwhile, the oxidation effect of S2O82− competes with the reduction effect of SO2. This study introduced the influence of flue gas into the research of the conversion of selenium in FGD slurry and indicate the effect of flue gas on the potential emission treatment techniques of selenium in FGD slurry.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.