Abstract

A split counter arrangement was used to investigate the absorption coefficient of the radiation which causes the discharge to spread along the wire of a counter after the triggering of a pulse. The counters used were filled with methylene bromide and argon at various pressures, and with ethyl alcohol and argon. The results indicate that the vapor dissipates electron energies, thereby reducing the number of photons produced during the discharge. It was also observed that the absorption coefficient is a function of the argon alone, from which it was concluded that photo-ionization of the argon is responsible for spreading the discharge along the wire. This behavior was also observed with helium and neon in combination with alcohol or methylene bromide.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.