The concurrent determination of pesticidal and non-pesticidal organotin compounds in several water matrices, using a simultaneous in situ ethylation and liquid–liquid extraction followed by splitless injection mode capillary gas chromatography with pulsed flame photometric detection, is described. The speciation analysis of nine organotin compounds includes low molecular weight–low boiling (non-pesticidal) and high molecular weight–high boiling analytes (pesticidal) of significant environmental interest. The minimum time for sodium tetraethylborate alkylation, using mechanical agitation, is determined to be 15 min in order to ensure the complete derivatization of the entire list of analytes. The utilization of a “hot needle” and a rapid injection rate is shown to be an efficacious means to eliminate “mass” or “needle” discrimination when determining the mixture of organotin compounds. Method detection limits are calculated to be in the low ng L − 1 range. The final method is applied to various water samples; storm water from the Cincinnati area demonstrated low native levels of three of the organotin compounds.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.