Abstract

Directed at the working conditions of waste discharging hall in a waste incineration power plant, put forward the design scheme of the horizontal scrubbing tower, used Eckert's current correlative graph and the Bain-Hogan correlation, determined the wind needed for treatment and size parameters of washing tower, worked out at the flooding point gas velocity and the wind resistance. Based on CREO, modeled a washing tower model, and established the analysis model of scrubbing tower bodies by using ANSYS. The calculation results indicate that the maximum deformation and stress are 1.9623mm and 87.7.7MPa, and all the main parameters meet the design requirements.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.