Abstract
The direct torque control (DTC) system of the traditional asynchronous motor has many disadvantages, such as complex modeling and large amount of calculation, In order to improve the dynamic performance of the DTC system of the asynchronous motor, a direct torque control system is put forward. It uses space vector analysis method to calculate electromagnetic torque and stator flux linkage of asynchronous motor directly, follows the change of the stator flux linkage and torque, omits the complicated calculation, reduces the dependence on motor parameters. The simulation model of the DTC system of the asynchronous motor was established using SIMULINK software package. The feasibility of method is proved in theory, The results of simulation show that the modeling and simulation of the system has good static and dynamic performance, control precision of the system is higher, the stability is better.