Abstract

The authors describe observations on the negative pulseless corona in air between plane and needle electrodes and reports the characteristics of the transition from the negative pulseless corona to spark breakdown by measuring the luminosity and the space potential of the discharge gap. For the measurement of the space potential, a triode tube electrometer was used. The luminosity near the plane electrode is strongest just before the spark breakdown, and the transition from negative pulseless corona to spark breakdown starts from the plane electrode. At the spark breakdown, the field intensity in this region is constant for gap length ranging from 8 to 16 mm. This field intensity is about 43 V cm-1 Torr-1. It is the condition of the transition from negative pulseless corona to spark breakdown that the relation alpha >or= eta is accomplished near the plane electrode.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.