Abstract

HL-2M is a new medium-sized tokamak with major radius of 1.78 m, minor radius of 0.65 m, and aspect ratio of 2.8 and will be finished soon. In the conceptual design, a double-pass, horizontal view, multi-channel far-infrared (FIR) laser interferometer/polarimeter system (at 432 μm) is proposed to simultaneously measure the phase change and the Faraday rotation for density and current profile reconstruction. A vertical CO2 dispersion interferometer system (with wavelength of 10.6 μm and 5.3 μm) is designed to measure the line density, which will mainly be used for density feedback. The performance of the system is expected to meet the requirement of the measurements on HL-2M, with phase accuracy ∼0.1°, time resolution ∼1 μs, spatial resolution ∼7.2 cm, and density measurement range of 1 × 10 18-1 ×1021 m-3.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.