Abstract

All the parametric formulas in the discontinuous current mode of CCPS are given in this paper. Due to the leakage inductance and distributed capacitance existing in the high voltage high frequency transformer, the charging current decreases as the load voltage increase. To solve the issue, a dual-mode modulation strategy between pulse frequency and pulse width modulation is taken. Finally, a capacitor charging power supply of 100V input and 1600V output is designed. The experimental results confirm the correctness of the theoretical analysis and modulation strategy.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.