Abstract
NOx emission, heat transfer, and high temperature air combustion (HiTAC) in a boiler of Mobin Petrochemical Complex, Iran was numerically studied. The comparison between the measured values and the CFD predicted results showed good agreement, which implied that the adopted combustion and NOx formation models are suitable for correctly predicting characteristics of the heat recovery steam generation (HRSG) boiler. The predicted results show that NOx emission within the boiler depends highly on temperature, as well as oxygen concentration. Moreover, the influence of the equivalence ratio at a fixed air mass flow rate on the flame temperature and NOx formation has been investigated.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.