Abstract

SummaryAt present, power converter systems with d.c.-link on the basis of hard switching dominate in the field of power electronics. However, higher switching frequencies are necessary to reduce the noise as well as the size and weight of passive energy stores in a lot of applications. There are two ways to realize soft switching processes in principle: Zero-Current-Switching (ZCS) and Zero-Voltage-Switching (ZVS). The paper describes the behaviour of NPT-IGBTs at hard and soft switching (ZVS, ZCS).The internal processes of the Non-Punch-Through (NPT)-structure are analysed on the basis of a new very accurate PSpice IGBT model.Additional measurements show that NPT-IGBTs possess a very good behaviour under hard switching conditions. By contrary to that Punch-Through (PT)-IGBTs offer the best features at soft switching.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.