Abstract

The reaction mechanism of raw dolomite was analysed.The test have been implemented.The effect was generalized.The result is: application of raw dolomite in converter can reduce lime 3.3 kg/t,light burning dolomite 7.2 kg/t,coolant7.4 kg/t,decrease cost 9.74¥/t.