Abstract
Chord length distributions for rectangular parallelepipeds of various relative dimensions were studied in relation to radiation hardness testing. For each geometry, a differential chord length distribution was generated using a Monte Carlo method to simulate exposure to an isotropic radiation source. The frequency and dose distributions of chord length crossings for each geometry, as well as the means of these distributions, are presented. In every case, the dose mean chord length was greater than the frequency mean chord length with a 34.5% increase found for the least extreme case of a cube. This large increase of the dose mean chord length relative to the frequency mean chord length demonstrates the need to consider rare, long-chord-length crossings in radiation hardness testing of electronic components.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.