Abstract

The results of experimental studies of the parameters (amplitude and duration) of a supershort avalanche electron beam (SAEB) generated in air at atmospheric pressure are presented. It is shown that the pulse duration of the beam current behind the foil from the entire area of the anode foil is larger than from small areas and depends on the cathode design. The number of electrons that are detected behind the 10-μm-thick Al foil is ∼6 × 1010 electrons, which corresponds to a SAEB amplitude of ∼100 A at a FWHM of the current pulse of ∼100 ps. An X-ray exposure dose per pulse of ∼1.8 mR was obtained using a 20-μm-thick copper foil. It was confirmed that the FWHM of a SAEB pulse is within ∼50 ps from small foil areas (with diameters of ∼7 mm or smaller).

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.