Through field static load test and pile shaft axial force test, field testing study is conducted on bearing behavior of NAKS-construction-method belled large-diameter PHC pipe pile; besides, the test result is compared with that of hammering-method PHC pipe pile and bored pile with same pile length and diameter under the same site condition. The result shows that the ultimate bearing capacity of NAKS-construction-method belled large-diameter PHC pipe pile is slightly inferior to hammering-method PHC pipe pile but obviously superior to that of bored pile. Compared with traditional hammering-method pipe pile, the pile side resistance of NAKS-construction-method belled pipe pile is smaller; however, the higher toe resistance will give better play to bearing capacity of bearing stratum of pile toe; moreover, it is found that under the action of ultimate load and failure load, the maximum settlement and final settlement of NAKS-construction-method belled pipe pile tip are obviously lower than that of other test piles, which is conductive to lessening foundation settlement of upper structure.