Abstract
A comprehensive shield test program for a hot cell complex, the Fuel Conditioning Facility at Argonne National Laboratory, has been completed with minimum radiation exposure to participants. The recently modified shielding design for two hot cells and their associated transfer paths for irradiated materials was analyzed and tested for attenuating gamma rays from mixed fission product sources. Testing was accomplished using 0.37 TBq (10 Ci) and 518 TBq (14,000 Ci) 60Co sources. Of specific concern were radiation levels around wall penetrations and the interface between transport casks and the cell floor. Detailed measurements were made for surfaces that bound the hot cells, a transfer tunnel between the two cells, and storage pits that extend below the floors of both cells. In addition to surface measurements, dose equivalent rates in adjacent corridors were determined when the larger source was exposed. Results indicate that with some administrative controls, the facility shields are adequate to meet the design criterion that limits annual dose to less than 10 mSv (1 rem) for facility workers.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.