Abstract

Testing has been completed for two lightly shielded areas that support operations in the Fuel Conditioning Facility at the Argonne National Laboratory site at the Idaho National Engineering Laboratory. Operational requirements dictated the use of a radiography source containing 0.44 TBq (12 Ci) of 192Ir to challenge reinforced concrete and steel shields that surround a decontamination, maintenance, and repair area for contaminated equipment used in hot cell operations. A more intense source containing 0.89 TBq (24 Ci) of 192Ir was used to test lead shot and steel shields around tanks in a radioactive liquid waste system and the boundaries of the room that contained it. Measurement procedures were developed to find design flaws and construction deficiencies while minimizing radiation exposure to test participants. While the shields are adequate to limit gamma ray deep dose equivalents to 10 mSv y(-1) (1 rem y(-1)) or less to facility personnel, several modifications were necessary to assure that the attenuation is adequate to keep dose rates less than 5 microSv h(-1) (0.5 mrem h(-1)) in normally occupied areas.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.