Abstract
The following table is the result of a series of tests carried out at East London College (University of London) on various methods of mounting flexible steel cables, in cable ends.The specimens were kindly supplied by Messrs. T. W. K. Clarke and Co.Cables Nos. 1 and 3 were fixed in the following manner. The ends were knotted and tinned, then inserted in sockets or cable ends, and solder run in.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.