Abstract

This study examined water quality, naturally-occurring radioactive materials (NORM), major ions, trace metals, and well flow data for water used and produced from start-up to operation of an oil and gas producing hydraulically-fractured well (horizontal) in the Denver-Julesburg (DJ) Basin in northeastern Colorado. Analysis was conducted on the groundwater used to make the fracturing fluid, the fracturing fluid itself, and nine flowback/produced water samples over 220days of operation. The chemical oxygen demand of the wastewater produced during operation decreased from 8200 to 2500mg/L, while the total dissolved solids (TDS) increased in this same period from 14,200 to roughly 19,000mg/L. NORM, trace metals, and major ion levels were generally correlated with TDS, and were lower than other shale basins (e.g. Marcellus and Bakken). Although at lower levels, the salinity and its origin appear to be the result of a similar mechanism to that of other shale basins when comparing Cl/Br, Na/Br, and Mg/Br ratios. Volumes of returned wastewater were low, with only 3% of the volume injected (11millionliters) returning as flowback by day 15 and 30% returning by day 220. Low levels of TDS indicate a potentially treatment-amenable wastewater, but low volumes of flowback could limit onsite reuse in the DJ Basin. These results offer insight into the temporal water quality changes in the days and months following flowback, along with considerations and implications for water reuse in future hydraulic fracturing or for environmental discharge.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call