Abstract

A novel two-dimensional tilt sensor with a large measurement range is demonstrated by using four fiber Bragg gratings (FBGs) attached on a cylindrical cantilever-based pendulum. Experimental results show that tilt accuracy of ±0.2° and resolution of 0.013° have been achieved in the range of -40° to 40°. The temperature effect is automatically eliminated without additional temperature compensation elements.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have