Abstract
The response of an E.R.C. Lyman-alpha hygrometer to humidity and temperature variations has been experimentally determined in a humidity calibration tunnel. The data are compared to a simple two-gas/two-line model to determine the errors made in atmospheric measurements of humidity variance and flux due to turbulent fluctuations of temperature. The model also was used to study the influence of path length on the hygrometer response. The emission by current Lyman-alpha sources of H2 molecular lines, even in small quantity, can cause temperature sensitivity errors much larger than expected in spectral functions of humidity or mixed humidity-temperature statistics. These errors largely depend on the quality of spectral emission, path length and mean humidity and temperature.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.