Abstract

Measurements of temperature traces in a rubber compound are carried out during injection molding cycle. The measurements are performed using a special temperature measuring device inserted into molds having a cylindrical cavity. The measurements indicate complex temperature traces with a minimum and a maximum during molding cycle. Calculations of tem perature field are performed based on the finite difference solution of the two- dimensional transient heat conduction equation with convective heat transfer on the boundary. The predicted temperature traces, although qualitative, cor rectly simulate experimental observations.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.