Abstract

The structural and electrical parameters of leakage inductance transformers can significantly affect the efficiency, noise, and vibration of microwave ovens. The paper proposed a new iron core structure with finite element modeling and simulations of a leakage inductance transformer by both the electromagnetic field and system design simulation software. Different silicon steel sheet models were used for the upper and lower parts of the proposed iron core to reduce the loss and heat of the leakage inductance transformer. The iron core scheme was changed from the traditional E-I type to the E-E type. The feasibility of the new iron core scheme was tested by numerical results which showed that the maximum temperature rise of the leakage inductance transformer decreased significantly.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.