Abstract

The control of a divided-wall column is more difficult than the control of a conventional two-column separation sequence for the separation of ternary mixtures because there is more interaction among control loops. In a previous paper, a control structure using four composition loops was shown to provide effective control of the purities of the three product streams and also achieve minimum energy consumption for both feed flow rate and feed composition disturbances. The numerical example studied the separation of benzene, toluene, and o-xylene. The four manipulated variables were reflux flow rate (R), side-stream flow rate (S), reboiler heat input (QR), and liquid split (βL) at the top of the wall. In this paper we explore the use of temperatures to avoid expensive and high-maintenance composition analyzers. Two types of temperature control structures are studied. In the first, three temperatures located in the main column and one temperature on the prefractionator side of the wall are used to adjust the...

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.