The distribution of fluid temperature near a branch pipe wall of a T-junction was investigated for the flow pattern of impinged penetration where the hot main flow impinged on the branch pipe wall and penetrated into the branch pipe. The velocity in the inlet of the main pipe was fixed at about 10 m/s and the inlet velocity of the branch pipe was changed in order to simulate the flow pattern. The fluid temperature near the pipe inner surface fluctuated due to the penetration of the hot main flow. The fluctuations, with a frequency range of 0.2 Hz to 2 Hz, caused relatively large temperature fluctuations. The time averaged temperature decreased monotonically in the upward direction of the branch pipe axis. In contrast, the temperature fluctuation range had a peak at a distance from the nozzle corner when the flow velocity in the inlet of the branch pipe was relatively low. It is important to consider the peak position of the temperature fluctuation range when designing the length of the thermal sleeve.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.