Abstract

Heat transfer in double pipe heat exchanger with circumference-rectangular grooves has been investigated experimentally. The volume flowrate of cold and hot water were varied to determine its influence on the approach temperature of the outlet terminals. In this experimental design, the grooves were incised in annular room that is placed on the outside surface of the inner pipe. The shell diameter is 38.1 mm and tube diameter 19.4 mm with 1 m length, which is made of aluminum. The flow pattern of the two fluids in the heat exchanger is a parallel flow. The working fluid is water with volume flow rate of 27.1, 23.8 and 19.8 l/minute. The temperature of water on the inlet terminals are 50±1°C for hot stream and 30±1°C for cold stream. Temperature measurements conducted on each terminal of the inlet and outlet heat exchanger. The results showed that the grooves induced the approach temperature. The change of the approach temperature from the grooves compared to that of without grooves decreased by 37.9%. This phenomenon indicates an increase in heat transfer process and performance of the heat exchanger. Groove improves the heat surface area of the inner pipe, increasing the momentum transfer and in the other hand, reducing the weight of heat exchangers itself.

Highlights

  • A heat exchanger is a heat transfer device that exchange heat between two or more process fluids at different temperature

  • Preliminary experiments were done on the double pipe heat exchanger without groove to establish the time series temperature and approach temperature

  • This data was used as a comparison to the data from the double pipe heat exchanger with groove

Read more

Summary

Introduction

A heat exchanger is a heat transfer device that exchange heat between two or more process fluids at different temperature. One of the heat exchanger is double pipe heat exchanger (DPHE). Their usual application is for small duties and they are suitable for high pressure and temperature. Another advantage is the design of DPHE serviceable than the other heat exchanger and can be connected in series or parallel. The effective temperature driving force is a measure of the potential for heat transfer that exists at the design conditions. Other method to measure thermal performance of heat exchanger is using temperature approach. Temperature approach referred to difference of temperature between hot and cold outlet of heat exchanger

Objectives
Methods
Results
Conclusion

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.