Abstract

The implementation of ultra-low emission (ULE) limits (SO2: 35 mg/m3, NOx: 50 mg/m3, PM: 10 mg/m3) promoted the development of flue gas treatment technologies in China. Pollutant control technology development for Chinese coal-fired power plants was summarized and an analysis of the applicability and cost of pollutant control technologies was conducted. Detailed data were collected from 30 ultra-low emission coal-fired units across China. Based on a cost analysis model, the average unit power generation incremental costs were 0.0144 and 0.0095 CNY/(kW·hr) for SO2 and NOx control technologies, respectively. The unit power generation incremental cost of twin spray tower technology was 7.2% higher than that of dual-loop spray tower technology. The effect of key parameters on operating cost was analyzed. The unit power generation incremental cost increased because of increments in the electricity price for SO2 control technology and the price of the reductant in NOx control technology. With high sulfur content or NOx concentration, the unit power generation incremental cost caused by pollutant control increased, whereas the unit pollutant abatement cost decreased. However, the annual operating hours or load increased, thereby leading to a decline in unit power generation incremental cost and unit pollutant abatement cost.