Abstract

Current standard practice for clinical radionuclide dosimetry utilizes reference phantoms, where defined organ dimensions represent population averages for a given sex and age. Greater phantom personalization would support more accurate dose estimations and personalized dosimetry. Tailoring phantoms is traditionally accomplished using operator-intensive organ-level segmentation of anatomic images. Modern mesh phantoms provide enhanced anatomical realism, which has motivated their integration within Monte Carlo codes. Here, we present an automatable strategy for generating patient-specific phantoms/dosimetry using intensity-based deformable image registration between mesh reference phantoms and patient CT images. This work demonstrates a proof-of-concept personalized dosimetry workflow, presented in comparison to the manual segmentation approach. A linear attenuation coefficient phantom was generated by resampling the PSRK-Man reference phantom onto a voxel grid and defining organ regions with corresponding Hounsfield unit (HU) reference values. The HU phantom was co-registered with a patient CT scan using Plastimatch B-spline deformable registration. In parallel, major organs were manually contoured to generate a "ground truth" patient-specific phantom for comparisons. Monte Carlo derived S-values, which support nuclear medicine dosimetry, were calculated using both approaches and compared. Application of the derived B-spline transform to the polygon vertices comprising the PSRK-Man yielded a deformed variant more closely matching the patient's body contour and most organ volumes as-evaluated by Hausdorff distance and Dice metrics. S-values computed for fluorine-18 for the deformed phantom using the Particle and Heavy Ion Transport code System showed improved agreement with those derived from the patient-specific analog. Deformable registration techniques can be used to create a personalized phantom and better support patient-specific dosimetry. This method is shown to be easier and faster than manual segmentation. Our study is limited to a proof-of-concept scope, but demonstrates that integration of personalized phantoms into clinical dosimetry workflows can reasonably be achieved when anatomical images (CT) are available.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.