Abstract

Abstract. MIPAS (Michelson Interferometer for Passive Atmospheric Sounding) is operating on the ENVIronmental SATellite (ENVISAT) since March 2002. After two years of nearly continuous limb scanning measurements, at the end of March 2004, the instrument was stopped due to problems with the mirror drive of the interferometer. Operations with reduced maximum path difference, corresponding to both a reduced-spectral-resolution and a shorter measurement time, were resumed on January 2005. In order to exploit the reduction in measurement time, the measurement scenario was changed adopting a finer vertical limb scanning. The change of spectral resolution and of measurement scenario entailed an update of the data processing strategy. The aim of this paper is the assessment of the differences in the quality of the MIPAS ozone data acquired before and after the stop of the operations. Two sets of MIPAS ozone profiles acquired in 2003–2004 (full-resolution measurements) and in 2005–2006 (reduced-resolution measurements) are compared with collocated ozone profiles obtained by GOMOS (Global Ozone Monitoring by Occultation of Stars), itself also onboard ENVISAT. The continuity of the GOMOS data quality allows to assess a possible discontinuity of the MIPAS performances. The relative bias and precision of MIPAS ozone profiles with respect to the GOMOS ones have been compared for the measurements acquired before and after the stop of the MIPAS operations. The results of the comparison show that, in general, the quality of the MIPAS ozone profiles retrieved from reduced-resolution measurements is comparable or better than that obtained from the full-resolution dataset. The only significant change in MIPAS performances is observed at pressures around 2 hPa, where the relative bias of the instruments increases by a factor of 2 from the 2003–2004 to 2005–2006 measurements.

Highlights

  • The atmospheric chemistry payload onboard the ENVIronmental SATellite (ENVISAT) of the European Space Agency (ESA) consists of three instruments that are capable to retrieve vertical concentration profiles of several trace gases from observations in the middle infrared (MIPAS), visible and ultraviolet (GOMOS and SCIAMACHY) spectral regions (Nett et al, 2001)

  • We will describe the results of the comparisons between GOMOS and MIPAS ozone profiles and we will try to highlight potential differences in the quality of MIPAS products retrieved from measurements at full- and at reduced-spectral-resolution

  • We report the mean absolute difference between MIPAS and GOMOS ozone Volume Mixing Ratio (VMR) as a function of pressure, with error bars representing the Standard Error on the Mean (SEM) values

Read more

Summary

Introduction

The atmospheric chemistry payload onboard the ENVIronmental SATellite (ENVISAT) of the European Space Agency (ESA) consists of three instruments that are capable to retrieve vertical concentration profiles of several trace gases from observations in the middle infrared (MIPAS), visible and ultraviolet (GOMOS and SCIAMACHY) spectral regions (Nett et al, 2001). All these sensors provide, as part of their level 2 operational products, heightresolved information on the ozone distribution from the upper troposphere to the mesosphere. Ceccherini et al.: Continuity of MIPAS-ENVISAT ozone data quality

Objectives
Results
Conclusion