Abstract

An experimental design required burn treatments for 10-m2 circular plots. We constructed a fire enclosure for the plots using sheetmetal, electrical conduit, and other commonly available materials. We field tested the enclosure in sagebrush-grass ecosystems in central Nevada and central Utah, and evaluated peak fire temperatures using small metal tags striped with temperature sensitive paint. We obtained average peak surface temperatures of 310, 307, and 381 degrees C in bare ground, under grass, and under shrub microsites, respectively, for the Nevada sites and 253, 299, and 337 degrees C for the same microsites, respectively, in Utah. Subsurface (2-cm depth) temperatures rarely exceeded 79 degrees C, the lowest temperature detectable by our method. The enclosure contained the fire and did not permit escape of any embers or firebrands. The fire enclosure, burn technique and temperature monitoring method used are inexpensive, easily deployed, and desirable for experiments where larger-scale burns are impractical.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.