Abstract

The technique of laparoscopic appendectomy has been modified several times in the past 20 years. In this report, we have described our modifications regarding the position of ports placement and closure of the base of appendix. Three surgeons successfully performed laparoscopic appendectomy in 108 cases with these modifications during the 3-year period. The first 10 mm port is placed in the periumbilical region. The second 10 mm and third 5 mm ports are inserted in the left and right side of abdomen below the pubic hairline respectively. Then the telescope is transferred from the periumbilical to the left suprapubic port. This mode of access leads to optimal ergonomics and cosmesis. For securing the base of appendix, only one Hem-o-lok clip (nonabsorbable polymer clip) is applied on each side. The use of Hem-o-lok clip is simple, safe and decreases the time and cost of laparoscopic appendectomy.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.