Abstract

Diagnostics of the technical condition of heat exchanger tube bundles is considered in the paper. The main problem is associated with the large total length of tubes in bundles and a limited time for examination. For examination of the internal clearance of pipes the method of acoustic pulse reflectometry, known in a science and technology, was used. This method was implemented in PAKT-04 device for express-inspection of heat exchangers. It is proposed for characterizing the wear of the tubes to introduce a generalized quantitative parameter called “defectiveness degree”. The parameter is determined by change of acoustic signal propagating in the tube. The value of defectiveness degree indicates the applicability the tube for operation in the heat exchanger. The results of measuring the parameter on different heat exchangers are discussed.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.