Abstract

To measure changes in tear-film lipid-layer thickness (LLT) and symptoms in patients with dry eye symptoms with and without Sjögren's syndrome after using a novel device. The device is designed to promote release of meibomian sebum into the tear film by delivering latent heat to the eyelids. Two prospective, controlled, randomised, observer-masked, single-intervention studies. Two independent studies were conducted in a major university hospital in the South West of England. The first study involved 24 patients with dry eye symptoms without Sjögren's [the PDE study] and the second study involved 31 patients with dry eye symptoms and Sjögren's syndrome (the SS study). The PDE study was randomised into two groups. Group I (12 patients) underwent 10 min of treatment with the activated device and Group II (12 patients) had no treatment. The SS study was similarly randomised into Group I (17 patients) and Group II (14 patients). The LLT and subjective alterations in ocular comfort of each subject were assessed prior and immediately after 5 and 30 min subsequent to the 10-min period. In the SS study, a further assessment was carried out at 60 min. In the PDE study, treated patients exhibited a bilateral increase of LLT at 5 min (right eyes, 1.2 levels, p<0.0005; left eyes, 1.0 levels, p<0.0005, Mann-Whitney) and at 30 min (right eyes, 0.7 levels, p<0.005; left eyes, 0.6 levels, p<0.005). Mean symptom scores improved in the treated group compared with the control group at 5 min (treatment group, +2.0; control group, +0.2; p<0.05) and 30 min (treatment group, +2.8; control group, +0.4; p<0.015). In the SS study, treated patients exhibited a bilateral increase of LLT, 5 min (right eyes, 0.5 levels, p<0.009; left eyes, 0.5 levels, p<0.005, Monte Carlo 2-tailed), 30 min (right eyes, 0.5 levels, p<0.007; left eyes 0.5 levels, p<0.002) and 60 min (right eyes, 0.3 levels, p<0.1; left eyes, 0.3 levels, p<0.05). There was no change in any of the control patients in any of the assessments. With regard to symptom scores, the mean change at 5 min measured +0.8 in the treatment group and remained relatively unchanged at +0.1 in the control group (p<0.1). At 30 min, this change measured +1.3 in the treatment group and +0.1 in the control group (p<0.03) and at 60 min, the change measured +1.5 in the treatment group and remained at +0.1 in the control group (p<0.02). Meibomian therapy with this novel device increases LLT and ocular comfort in patients with dry eye symptoms with and without Sjögren's syndrome.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.