Abstract

We leverage the photo-conductance (PC) effect in doped phase-shifter heaters for both controlling and calibrating Mach-Zehnder interferometer (MZI) switch elements. Both the steady-state and the transient response are experimentally characterized, and compact models for the PC current are developed. Utilizing the PC effect, a topology-agnostic algorithm is then outlined. The calibration procedure is experimentally verified against calibration with external photo-detectors using a non-blocking 4×4 Benes switch consisting of six 2×2 MZIs. It is shown that our PC-based approach agrees with the PD-based procedure within less than 2.5% of difference between the obtained calibrated values. Based on the calibrated PC values, all possible routing configurations are measured for extinction ratio (9.92-21.51dB), insertion loss (0.88-4.59dB), and exhibiting performances far below the 7% FEC limit (bit error rate of 3.8 × 10- 3) using 25 Gbps 4-level pulse-amplitude-modulation signals (PAM4).

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.