Abstract

This study aimed to investigate the cortical response characteristics evoked by natural teeth and implants. Five cats were subjected to intrinsic signal optical imaging to measure the cortical responses evoked by natural teeth and implants. The difference in tactile sensation between the implant and natural tooth was compared in detail at the cortical response level. Some similarities were observed between the implants and natural teeth. The stimulating-response curves of the implants and natural teeth were generally S-curves, and both implants and natural teeth preferred labial-lingual direction stimulation. The implants and natural teeth differed in terms of their tactile sensitivity: implants were weaker than natural teeth in terms of both static and dynamic sensitivity. However, after saturation, there was no significant difference in tactile strength between implants and natural teeth. Both natural teeth and implants are able to distinguish the tactile strength and stimulation direction. Although implants are less sensitive than the natural tooth, the maximal tactile function and directional preference of implants are similar to those of natural teeth.