A series of innovative flame retardants containing N-Si and N-O-Si bonds have been synthesized. Their chemical structures were verified by nuclear magnetic resonance (NMR) spectroscopy and thermal stabilities determined by thermogravimetric analysis (TGA). The results indicate that their thermal and hydrolytic stabilities could be adjusted by fine tuning their silylamine (N-Si) and siloxyamine (N-O-Si) skeletons. Thus, the substituents bonded to the phthalimides, such as diphenylmethylsilyl, dimethylphenylsilyl, diphenyl‑tert-butylsilyl, triisopropylsilyl or diphenylmethylsiloxy; whichever was attached to the imide played a significant role on its thermal and hydrolytic properties. Upon thermal dissociation, the N-Si and N-O-Si compounds were shown to yield aminyl, silyl and oxygen-centered radicals that provided fire proofing effect in polypropylene (PP) films alone and a synergistic effect in combination with conventional phosphorous flame retardant in PP, linear low-density polyethylene (LLDPE) and epoxy resins (EP). Their efficacy as flame retardants alone in thin PP films were evaluated according to the DIN4102-B2 test. Both N-Si and N-O-Si significantly slowed down the burning of PP films. Moreover, their potential as adjuvants with a conventional phosphorous based flame retardant, i.e., spirocyclic phosphonate (AFLAMMIT® PCO 900) in PP and EP resins was evaluated according to the UL-94 V fire standard. A synergistic effect was observed when the phosphorous flame retardant was combined with either N-Si or N-O-SI containing compounds, since none of the flame retardants by themselves could provide V-0 rating in the UL94-V test in PP, LLDPE or EP resins even at much higher loadings. The thermogravimetric analysis carried out under inert atmosphere revealed enhanced and earlier onset of decomposition and thermal activation of phosphorous based flame retardant in the presence of N-Si or N-O-Si in comparison to spirocyclic phosphonate, N-Si or N-O-Si used alone, respectively. The interaction of the phosphorus flame retardant with N-Si was verified by 31P NMR.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.