The Synthane high-Btu coal-conversion pilot plant was shut down following the discovery of a leaking crack in a Type 304 stainless steel weld neck flange that is part of a preheat line of the gasifier. The flange was exposed to approximately 2.9 Ms (approximately 800 h) of operation at 4.3 MPa (600 psig) steam at 399/sup 0/C (750/sup 0/F). Several additional nonleaking intergranular cracks were also found at the inside diameter surface of the weld neck. The cracks are believed to be due to intergranular stress corrosion. Also, the heat-affected zone near the weld and/or chlorides may have contributed to the cracking. Metallography revealed that slip and precipitation on slip planes and grain boundaries had occurred. This suggests that the region of the flange near the leak had undergone considerable plastic deformation prior to a heat treatment.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.