Abstract

Weld neck flanges on piping systems are susceptible to flange face corrosion when they are exposed to corrosive environments. This paper examines the maximum amount of corrosion a weld neck flange face could tolerate without loosing structural integrity and hence the flange is fit for service. A parametric study using finite element method was used to examine the entire range of weld neck flanges listed in ASME B16.5 Code, Pipe Flanges and Flanged Fittings. From the study, a number of tables were developed limiting the amount of corrosion for the various classes and sizes of flanges.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.